Year: 2013 Version: 2.5.1 Platform: PC (Windows) Compatibility with Windows7: unknown Language: english Pill: crack by b8361811 Description: The learning objective is to understand and operate the entire engine room system in a safe, timely and cost-effective manner. Whether choosing a NEPTUNE full mission or PC desktop, students or employees will learn a vast array of skills thanks to the pedagogical values and high fidelity realism the NEPTUNE simulator systems offer. NEPTUNE Engine Room Simulator models are certified by Det Norske Veritas according to Standard for Certification of Maritime Simulators No. 2.14 and cover Class A, B and C – fully compliant with STCW's latest requirements for training purposes. http://www.youtube.com/watch?v=ZhJPnQsADiw MC90-V v.2.5.1 CRACK by b8361811 MC90-V2.3 +CRACK
Hey, I have a problem to start the program .... after I click on simulation.exe this failure is coming: "missing argument: -p <plant path>" and when I start the shortcuts on the desktop: https://seatracker.ru/i/p/dd/d9/ddd902f5e5f8c050c3a728f7721b77ea.jpg I used the crack at from the image file please help me Thanks ! :) by the way, I use win 10 ....
Instructor: To create an initial condition, "play" until desired running status is obtained. This is done in the same fashion as running an actual plant. Opening valves and starting pumps until a stable running condition on different levels is achieved. When satisfied with simulator situation, chose display INITIAL CONDITION and click on CREATE. Type in name of condition and press enter Fixed process Instructor can set some systems in permanent no alarms condition. Useful when sub systems are to be simulated without disturbances Instructor: A scenario with an initial condition must be available and chosen. This will be indicated on pictures right side. To create, click on software button CREATE and click on one of the buttons M01 to M40 and type in chosen name. IMPORTANT: When a malfunction name has been typed and ENTERED, a prompt will ask you which TAG name is wanted. THIS TAG NAME MUST BE WRITTEN WITH FULL STYLE NAME AND NUMBER DIRECTLY COPIED FROM MALFUNCTION LIST. IN ADDITION TYPE IN EITHER _S OR .S. OTHERWISE TAG WILL NOT ENTER. WHEN PROMPT CHANGES COLOUR, IT WILL BE WRITTEN F.EX. M0201_S , AND YOU ARE ALLOWED TO CONTINUE. In section VALUE, active and passive values are entered. When prompted, type in values either digital (0,1,2 etc.) or analog in percentage of max values ACTIVE Value entered is value when fault is activated. Either one triggered as one continuos fault or as repeating fault. PASSIVE Value entered is starting level. That is condition of operation before fault is activated. UNIT Engineering unit or percentage. Not necessary to be entered. Action Editor: Allows editing of actions, i.e. somebody stopping a pump unintentionally.. Active in instructor mode only. Using and creating actions as malfunction editor. Input of tag names similar to malfunctions editor, adding period S or underscore S after tag. When starting a scenario, wanted malfunctions and action to be performed during simulation must be chosen by clicking on software buttons. Changing colours will indicate which buttons are activated. In front of each buttons is a light with 2 circles. Inner circle lit means that READING is active, meaning set intervals are reached, and action started. Outer circle lit means action is activated, but waiting for set time interval to be reached in order to switch action on. Time Editor: Allows editing of response time. Active only in instructor mode. Malfunction Editor: Allows editing of malfunctions during simulation. Instructor: A scenario with an initial condition must be available and chosen. This will be indicated on pictures right side. To create, click on software button CREATE and click on one of the buttons M01 to M40 and type in chosen name. IMPORTANT: When a malfunction name has been typed and ENTERED, a prompt will ask you which TAG name is wanted. THIS TAG NAME MUST BE WRITTEN WITH FULL STYLE NAME AND NUMBER DIRECTLY COPIED FROM MALFUNCTION LIST. IN ADDITION TYPE IN EITHER _S OR .S. OTHERWISE TAG WILL NOT ENTER. WHEN PROMPT CHANGES COLOUR, IT WILL BE WRITTEN F.EX. M0201_S , AND YOU ARE ALLOWED TO CONTINUE. In section VALUE, active and passive values are entered. When prompted, type in values either digital (0,1,2 etc.) or analog in percentage of max values.
hi can i ask for a favor? how can i get or install this software mc90? please help me because i need it so. ive been trying to search the file but it doesn't work.
Вы не можете начинать темы Вы не можете отвечать на сообщения Вы не можете редактировать свои сообщения Вы не можете удалять свои сообщения Вы не можете голосовать в опросах Вы не можете прикреплять файлы к сообщениям Вы не можете скачивать файлы
Kongsberg Norcontrol Neptune Simulator - MC90-V
Year: 2013
Version: 2.5.1
Platform: PC (Windows)
Compatibility with Windows7: unknown
Language: english
Pill: crack by b8361811
Description: The learning objective is to understand and operate the entire engine room system in a safe, timely and cost-effective manner. Whether choosing a NEPTUNE full mission or PC desktop, students or employees will learn a vast array of skills thanks to the pedagogical values and high fidelity realism the NEPTUNE simulator systems offer.
NEPTUNE Engine Room Simulator models are certified by Det Norske Veritas according to Standard for Certification of Maritime Simulators No. 2.14 and cover Class A, B and C – fully compliant with STCW's latest requirements for training purposes.
http://www.youtube.com/watch?v=ZhJPnQsADiw
MC90-V v.2.5.1 CRACK by b8361811
MC90-V2.3 +CRACK
Some comments
HOW TO CRACK MC90-V v.2.5.1 (old way)adita comments
MC90-V_Simulator_-_2.5.1.0228.rar
Скачать [14 KB]
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
I have a problem to start the program ....
after I click on simulation.exe this failure is coming:
"missing argument: -p <plant path>"
and when I start the shortcuts on the desktop:
https://seatracker.ru/i/p/dd/d9/ddd902f5e5f8c050c3a728f7721b77ea.jpg
I used the crack at from the image file
please help me
Thanks ! :)
by the way, I use win 10 ....
Поделиться
To create an initial condition, "play" until desired running
status is obtained. This is done in the same fashion as
running an actual plant. Opening valves and starting
pumps until a stable running condition on different levels is
achieved.
When satisfied with simulator situation, chose display
INITIAL CONDITION and click on CREATE. Type in
name of condition and press enter
Fixed process
Instructor can set some systems in permanent no alarms
condition. Useful when sub systems are to be simulated
without disturbances
Instructor:
A scenario with an initial condition must be available and
chosen. This will be indicated on pictures right side. To
create, click on software button CREATE and click on one
of the buttons M01 to M40 and type in chosen name.
IMPORTANT: When a malfunction name has been typed
and ENTERED, a prompt will ask you which TAG name is
wanted.
THIS TAG NAME MUST BE WRITTEN WITH FULL
STYLE NAME AND NUMBER DIRECTLY COPIED
FROM MALFUNCTION LIST. IN ADDITION TYPE
IN EITHER _S OR .S. OTHERWISE TAG WILL NOT
ENTER. WHEN PROMPT CHANGES COLOUR, IT
WILL BE WRITTEN F.EX. M0201_S , AND YOU
ARE ALLOWED TO CONTINUE.
In section VALUE, active and passive values are entered.
When prompted, type in values either digital (0,1,2 etc.) or
analog in percentage of max values
ACTIVE Value entered is value when fault is activated.
Either one triggered as one continuos fault or as repeating
fault.
PASSIVE Value entered is starting level. That is condition
of operation before fault is activated.
UNIT Engineering unit or percentage. Not necessary to be
entered.
Action Editor:
Allows editing of actions, i.e. somebody stopping a pump
unintentionally..
Active in instructor mode only.
Using and creating actions as malfunction editor. Input of
tag names similar to malfunctions editor, adding period S
or underscore S after tag. When starting a scenario, wanted
malfunctions and action to be performed during simulation
must be chosen by clicking on software buttons. Changing
colours will indicate which buttons are activated. In front
of each buttons is a light with 2 circles. Inner circle lit
means that READING is active, meaning set intervals are
reached, and action started.
Outer circle lit means action is activated, but waiting for set
time interval to be reached in order to switch action on.
Time Editor:
Allows editing of response time.
Active only in instructor mode.
Malfunction Editor:
Allows editing of malfunctions during simulation.
Instructor:
A scenario with an initial condition must be available and
chosen. This will be indicated on pictures right side. To
create, click on software button CREATE and click on one
of the buttons M01 to M40 and type in chosen name.
IMPORTANT: When a malfunction name has been typed
and ENTERED, a prompt will ask you which TAG name is
wanted.
THIS TAG NAME MUST BE WRITTEN WITH FULL
STYLE NAME AND NUMBER DIRECTLY COPIED
FROM MALFUNCTION LIST. IN ADDITION TYPE
IN EITHER _S OR .S. OTHERWISE TAG WILL NOT
ENTER. WHEN PROMPT CHANGES COLOUR, IT
WILL BE WRITTEN F.EX. M0201_S , AND YOU
ARE ALLOWED TO CONTINUE.
In section VALUE, active and passive values are entered.
When prompted, type in values either digital (0,1,2 etc.) or
analog in percentage of max values.
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
Поделиться
how can i get or install this software mc90?
please help me because i need it so.
ive been trying to search the file but it doesn't work.
Поделиться
I got this msg after running the simulator. Thank you.
Поделиться