zxc ® 18-Ноя-2013 22:09

Kongsberg Norcontrol Neptune Simulator - MC90-V


Year: 2013
Version: 2.5.1
Platform: PC (Windows)
Compatibility with Windows7: unknown
Language: english
Pill: crack by b8361811
Description: The learning objective is to understand and operate the entire engine room system in a safe, timely and cost-effective manner. Whether choosing a NEPTUNE full mission or PC desktop, students or employees will learn a vast array of skills thanks to the pedagogical values and high fidelity realism the NEPTUNE simulator systems offer.
NEPTUNE Engine Room Simulator models are certified by Det Norske Veritas according to Standard for Certification of Maritime Simulators No. 2.14 and cover Class A, B and C – fully compliant with STCW's latest requirements for training purposes.
http://www.youtube.com/watch?v=ZhJPnQsADiw
MC90-V v.2.5.1 CRACK by b8361811
MC90-V2.3 +CRACK

MC90-V_Simulator_-_2.5.1.0228.rar

Скачать [14 KB]

Спасибо
b8361811 18-Мар-2016 16:02
MC90-V v.2.5.1 crack
Вложение Simulator.zip (228 KB, Скачано: 4481 раз)
OberstMarley 30-Апр-2016 11:27
Hey,
I have a problem to start the program ....
after I click on simulation.exe this failure is coming:
"missing argument: -p <plant path>"
and when I start the shortcuts on the desktop:
https://seatracker.ru/i/p/dd/d9/ddd902f5e5f8c050c3a728f7721b77ea.jpg
I used the crack at from the image file
please help me
Thanks ! :)
by the way, I use win 10 ....
adita 02-Май-2016 09:32
Instructor:
To create an initial condition, "play" until desired running
status is obtained. This is done in the same fashion as
running an actual plant. Opening valves and starting
pumps until a stable running condition on different levels is
achieved.
When satisfied with simulator situation, chose display
INITIAL CONDITION and click on CREATE. Type in
name of condition and press enter
Fixed process
Instructor can set some systems in permanent no alarms
condition. Useful when sub systems are to be simulated
without disturbances
Instructor:
A scenario with an initial condition must be available and
chosen. This will be indicated on pictures right side. To
create, click on software button CREATE and click on one
of the buttons M01 to M40 and type in chosen name.
IMPORTANT: When a malfunction name has been typed
and ENTERED, a prompt will ask you which TAG name is
wanted.
THIS TAG NAME MUST BE WRITTEN WITH FULL
STYLE NAME AND NUMBER DIRECTLY COPIED
FROM MALFUNCTION LIST. IN ADDITION TYPE
IN EITHER _S OR .S. OTHERWISE TAG WILL NOT
ENTER. WHEN PROMPT CHANGES COLOUR, IT
WILL BE WRITTEN F.EX. M0201_S , AND YOU
ARE ALLOWED TO CONTINUE.
In section VALUE, active and passive values are entered.
When prompted, type in values either digital (0,1,2 etc.) or
analog in percentage of max values
ACTIVE Value entered is value when fault is activated.
Either one triggered as one continuos fault or as repeating
fault.
PASSIVE Value entered is starting level. That is condition
of operation before fault is activated.
UNIT Engineering unit or percentage. Not necessary to be
entered.
Action Editor:
Allows editing of actions, i.e. somebody stopping a pump
unintentionally..
Active in instructor mode only.
Using and creating actions as malfunction editor. Input of
tag names similar to malfunctions editor, adding period S
or underscore S after tag. When starting a scenario, wanted
malfunctions and action to be performed during simulation
must be chosen by clicking on software buttons. Changing
colours will indicate which buttons are activated. In front
of each buttons is a light with 2 circles. Inner circle lit
means that READING is active, meaning set intervals are
reached, and action started.
Outer circle lit means action is activated, but waiting for set
time interval to be reached in order to switch action on.
Time Editor:
Allows editing of response time.
Active only in instructor mode.
Malfunction Editor:
Allows editing of malfunctions during simulation.
Instructor:
A scenario with an initial condition must be available and
chosen. This will be indicated on pictures right side. To
create, click on software button CREATE and click on one
of the buttons M01 to M40 and type in chosen name.
IMPORTANT: When a malfunction name has been typed
and ENTERED, a prompt will ask you which TAG name is
wanted.
THIS TAG NAME MUST BE WRITTEN WITH FULL
STYLE NAME AND NUMBER DIRECTLY COPIED
FROM MALFUNCTION LIST. IN ADDITION TYPE
IN EITHER _S OR .S. OTHERWISE TAG WILL NOT
ENTER. WHEN PROMPT CHANGES COLOUR, IT
WILL BE WRITTEN F.EX. M0201_S , AND YOU
ARE ALLOWED TO CONTINUE.
In section VALUE, active and passive values are entered.
When prompted, type in values either digital (0,1,2 etc.) or
analog in percentage of max values.
  • Ответить

Текущее время: Сегодня 00:30

Часовой пояс: GMT + 3